Top Navigation  
 
U.S. Flag waving
Office Hours Momday - Friday  8 am - 5 pm Pacific 1-800-835-2418
 
Facebook   YouTube   Twitter
 
 
Backwoods Home Magazine, self-reliance, homesteading, off-grid

Features
 Home Page
 Current Issue
 Article Index
 Author Index
 Previous Issues
 Print Display Ads
 Print Classifieds
 Newsletter
 Letters
 Humor
 Free Stuff
 Recipes
 Home Energy

General Store
 Ordering Info
 Subscriptions
 Kindle Subscriptions
 ePublications
 Anthologies
 Books
 Back Issues
 Help Yourself
 All Specials
 Classified Ad

Advertise
 Web Site Ads
 Magazine Ads

BHM Blogs
 Ask Jackie Clay
 Massad Ayoob
 Claire Wolfe
 James Kash
 Where We Live
 Behind The Scenes
 Dave on Twitter
Retired Blogs
 Oliver Del Signore
 David Lee
 Energy Questions
 Bramblestitches

Quick Links
 Home Energy Info
 Jackie Clay
 Ask Jackie Online
 Dave Duffy
 Massad Ayoob
 John Silveira
 Claire Wolfe

Forum / Chat
 Forum/Chat Info
 Enter Forum
 Lost Password

More Features
 Contact Us/
 Change of Address
 Write For BHM
 Meet The Staff
 Meet The Authors
 Disclaimer and
 Privacy Policy


Retired Features
 Country Moments
 Links
 Feedback
 Radio Show


Link to BHM

Get Powered Up! Certified Energy Manager Jeff Yago answers your alternative energy questions

Wondering about a great new energy-saving device
you found on the Internet? Then CLICK HERE!

Sorry. Jeff no longer answers questions online.
This will remain as a searchable
resource for all BHM website visitors.



Archive for the ‘Sealed’ Category

 

Battery or Inverter Problem?

Thursday, December 11th, 2008

Dear Jeff,

In May last year, I purchased a 3KVA 24 volts inverter (Victron model) from a local distributor along with 4 units of 12 volts 200AH wet batteries connected 2 in parallel to meet the 24 volts required by the inverter. However less than 2 months into the use of the system 2 batteries failed and the supplier replaced then with 2 new batteries of the same make. A short while later (about 2 months again) 2 batteries failed again. The supplier advised that I should replace the batteries with dry cell deep cycle batteries which cost about twice the former units which I did. Now just about 8 months into the use of these deep cycle batteries, the run time provided by these batteries have dropped from about 24 hours to less than 4 hours.

I have contacted the supplier and at first he said the inverter needed servicing which he then carried out but the run time has remained the same. He now says the batteries may have failed since according to him the unit is operating efficiently. My problem now is that I am weary about investing in new batteries which are expensive since they might fail again.

What do you think might be the problem and is there a way I can tell what happened to the batteries.

Regards

Eme Iheanacho

Eme:

You have not provided enough information for me to help. For example, is this inverter being used as a backup power system and only draws down the batteries during a power outage. Is this an off-grid system and the inverter is re-charging the batteries using a generator?

Here are a few points without knowing how this is being used. It sounds like the inverter is over-charging or under-charging the batteries. Have the charger set-points been adjusted for the batteries you have? If I had this many failures in less than 2 months as you describe, I would be packing this equipment up and sending it back for a refund. I would NOT switch to gel or AGM sealed batteries. If you are destroying wet cells this fast, you will really destroy a sealed battery as they are even more sensitive to improper charging.

Good luck,

Jeff Yago

Dear Jeff,

Thank you for your response. The inverter is being used solely as a back up power system when there is a power outage. I also have a generator. I had it before the inverter and now use it to run heavier loads or when the outage has lasted for very long.

And I wish I had packed the inverter up and returned it then but I felt that maybe the batteries were faulty.

Regards

Eme

Eme:

Even though I did not have all the information about your system when I made my first comment, I feel like my suggestions are still true after reading your followup information. In standby mode where a grid-connected inverter is only being used as backup several times a year during a brief power outage, there is very little battery charging going on and the inverter should only be providing a small “maintain” charge to offset any standby losses in the batteries. Wet cell batteries may not be the best choice for this type of application as you will need to simulate a power outage every few months to force the batteries to go through a discharge and re-charge cycle to keep the electrolyte mixed. Wet cell batteries are very forgiving of poor charging performance and when over-charged they usually just need more watering. However, if you switch to sealed gel or AGM batteries which are better for stand-by applications before you solve this charging problem, you will just destroy more expensive batteries because they cannot be re-filled once they are dried out by over-charging.

Either you have a very good-quality inverter that has the wrong charging set-points programmed in, or you have a very defective inverter that is over-charging the batteries and I would not keep buying more batteries until you are sure which is true. I am really surprised your dealer is suggesting more batteries when there is clearly a problem with the charging.

Good Luck,